Operating Manual
COST CONTROL - POWER
CONSUMPTION MONITOR
Contents
Introduction 1
Intended Use 2
Safety Precautions 3
The Cost Control 4
Features 5
Cost Monitoring 6
Cost Forecasting 7
Instantaneous Power Consumption 8
The Maximum Load Power Display 9
Total Energy Consumption Display 10
Setting up 11
Tariff setting mode 12
Using Cost Control 13
Replacing batteries 14
Extra Notes 15
Maintenance 16
Specifications 17
Liability Disclaimer 18
1. INTRODUCTION:
The Cost Control Power Consumption Monitor is a
state-of-the-art power-monitoring socket that is highly
accurate and easy to use. Please read this entire
instructional manual before using the Cost Control so
Vue de la page 0
1 2 3 4 5 6 ... 17 18

Résumé du contenu

Page 1 - CONSUMPTION MONITOR

1Operating Manual COST CONTROL - POWER CONSUMPTION MONITOR Contents Introduction 1 Intended Use 2 Safety Precautions 3 The Cost Control

Page 2

10Note: The appliance should be operated as normal, for hints on this see the “Extra Notes” section. 13. USING THE COST CONTROL: Using the Cost Con

Page 3

11 When the monitoring of an electrical appliance is complete; simply turn the appliance off; remove the Cost Control from the outlet and the

Page 4

12be reset to zero (as was done in Setting Up – step 11 above). 14. REPLACING THE BATTERIES: A low power battery usually reduces the contrast of the

Page 5

1315. EXTRA NOTES: The electrical appliance connected to the Cost Control should always be operated as normal if forecasting of the cost is required

Page 6

14 Example 1: A lamp is plugged into the Cost Control and operated every evening: Day 1 from 6:00p.m. to 8:00p.m. Day 2 from 7:00p.m. to 9:00p.m. Da

Page 7

15recommended to keep the appliance plugged into the Cost Control for several days before taking the reading. If a reading is taken after the applia

Page 8

1617. SPECIFICATIONS: • Absolute max. rating (short time) -Load : 1800W max 4W min -Current : 15A • Op

Page 9

17• Damage caused by neglect, misuse or failure to comply with this manual will invalidate the warranty of this product. • The manufacturer cannot

Page 10

18INFORMATION. THIS PRODUCT IS NOT A TOY. KEEP OUT OF CHILDRENS’ REACH. This warranty gives you specific legal rights. You may also have other rig

Page 11

2you can fully take advantage of all the features it has to offer. 2. INTENDED USE: The Measuring range of the Cost Control is from approximately 3W

Page 12

3In order to maintain perfect condition and guarantee safe operation of this product, the user must observe the Intended Use, Safety Precautions, and

Page 13

4• In commercial institutions the safety regulations of the alliance of commercial professional association for electrical installations and product

Page 14

54. THE COST CONTROL: LCD TARRIFF Key COST Key POWER Key Socket Battery Cover Plug

Page 15

6 5. FEATURES: • Cost monitoring • Cost forecasting (day, month, year) • Instantaneous power consumption (Watt) • Maximum load power display (Ma

Page 16

7When an electrical appliance is plugged into the Cost Control, by pressing the “POWER” key, the instantaneous power (Watts) being used at that preci

Page 17

8• Any preset values in the “TOTAL COST” display that the user has not set in must be reset to zero to ensure accurate readings. To do this, simply

Page 18

9 • Press and hold the “TARIFF” key (approximately 3 seconds) until the first digit on the right hand side starts flashing. • Press the “POWER” key

Commentaires sur ces manuels